EFRP-S3803 |
1500W Output Power
N+1 Redundant Configuration
Dimensions: 101.2(W) x 126.1(H) x 300(D) mm |
 |
 |
Features : |
| |
High Efficiency≧80%
N+1 Redundant Design
PMBus Support
Power Failure Alarm
0~40℃ Working Temperature |
General Specifications : |
| |
Input Range: 100 to 240 VAC, +/-10%
Power Factor: ≧ 0.97 minimum
Efficiency: ≥80%
Hold Up Time: 17ms @ 80% Load
Short Circuit Protection
Over Current Protection
Over Voltage Protection
No Load Operation
MTBF >100,000 Hours@25℃
Operating Temperature: 0 to 40 ℃
Operating Humidity: 20 to 90 %
EMI/RFI: CE, FCC class B
Safety: UL, TUV, CCC, CB, BSMI |
Regulation, Ripple & Noise: |
| |
|
Output
|
+3.3V
|
+5V
|
+12V
|
-12V
|
+5Vsb
|
|
Load Regulation
|
+5/-4%
|
+5/-3%
|
+5/-4%
|
+9/-5%
|
+5/-3%
|
|
Cross Regulation
|
+5/-4%
|
+5/-3%
|
+5/-4%
|
+9/-5%
|
+5/-3%
|
|
Line Regulation
|
± 1%
|
± 1%
|
± 1%
|
± 1%
|
± 1%
|
|
Ripple & Noise
|
60mV
|
60mV
|
120mV
|
120mV
|
60mV
|
|
Input and Output Ratings: |
| |
|
Input
|
Output
|
|
Voltage
|
Frequency
|
Current
|
Watt
|
Load
|
+3.3V
|
+5V
|
+12V
|
-12V
|
+5Vsb
|
|
100~240VAC
|
47-63 Hz
|
23-11.5A
|
1500W
|
Max. Load
|
50A
|
50A
|
123A
|
0.5A
|
3.5A
|
|
Min. Load
|
0A
|
0A
|
1A
|
0A
|
0.1A
|
|
|
NOTE:
- The +5 & +3.3 Volt total output shall not exceed 280 W.
- The maximum output power shall not exceed 1500W.
- Noise bandwidth is from DC to 20 MHz.
|
Agency Requirements : |
| |
Harmonic: Meet EN61000-3-2
EMI/RFI: CE, FCC class B
Safety: UL, cUL, TUV, CB, CCC |
|