EFRP-S2157H |
150W Output Power
N+1 Redundant Configuration
Dimension: 106(W) x 41.5(H) x 260(D) mm |
 |
|
Features : |
| |
N+1 Redundant Design
High Efficiency≧80%
Power Failure Alarm
Front Access Ability
0~50℃ Working Temperature |
General Specifications : |
| |
Input Range: 100 to 240 VAC, +/-10%
Power Factor: ≧0.95 minimum
Efficiency: ≧80% @ 115VAC
Hold Up Time: 18ms @ 80% Load
Short Circuit Protection
Over Current Protection
Over Voltage Protection
No load Operation
Over Temperature Protection
MTBF >100,000 Hours@25℃
Operating Temperature: 0 to 50 ℃
Operating Humidity: 20 to 90 %
EMI/RFI: CE, FCC class B
Safety: UL, CB, TUV, CCC, BSMI |
Regulation, Ripple & Noise: |
| |
|
Output
|
+3.3V
|
+5V
|
+12V
|
-12V
|
+5Vsb
|
|
Load Regulation
|
± 5%
|
± 5%
|
± 5%
|
± 5%
|
± 5%
|
|
Line Regulation
|
± 1%
|
± 1%
|
± 1%
|
± 1%
|
± 1%
|
|
Ripple & Noise
|
50mV
|
50mV
|
120mV
|
120mV
|
50mV
|
|
Input and Output Ratings: |
| |
|
Input
|
Output
|
|
Voltage
|
Frequency
|
Current
|
Load
|
+3.3V
|
+5V
|
+12V
|
-12V
|
-5V
|
+5Vsb
|
|
100-240 VAC
|
47-63 Hz
|
2.5-1.25A
|
Max. Load
|
15A
|
15A
|
11A
|
0.5A
|
-
|
2A
|
| Min. Load |
0.5A
|
0.5A
|
0.8A
|
0A
|
-
|
0A
|
|
|
NOTE:
- The +3.3 &+5 Volt total outputs shall not exceed 120W.
- Noise bandwidth is from DC to 20 MHz
|
|