EPAP-300 |
300W Output Power
5 Output Rails with PFC
ATX12V Application
For PS2 Redestal System
Over Temperature Protection
Dimension: 149.6(W) x 86(H) x 140(D) mm |
Features : |
| |
ATX12V 5 Output Rails
Universal Power Input
Over Power Protection
Short Circuit Protection
Over Current Protection
Over Voltage Protection
Remote DS Sense on +5V and +3.3V
Active Power Factor Correction
MTBF >100,000 Hours |
General Specifications : |
| |
Input Range:100 to 240 VAC, ± 10%
Power Factor: 0.95 minimum
Efficiency: 70% minium, at full load
PSON (Remote ON/OFF):TTL Signal
Power Good: 100 to 1000ms, TTL signal
Cooling Fan: 80x80x20mm
Operating Temperature:0 to 50ºC
Operating Hnmidity:20 to 90ºC |
Regulation, Ripple & Noise: |
| |
|
Output
|
+3.3V
|
+5V
|
+12V1
|
+12V2
|
+12V3
|
+12V4-
|
-5V
|
-12V
|
+5Vsb
|
|
Load Regulation
|
± 5%
|
± 5%
|
± 5%
|
-
|
-
|
-
|
-
|
± 10%
|
± 5%
|
|
Cross Regulation
|
± 5%
|
± 5%
|
± 5%
|
-
|
-
|
-
|
-
|
± 10%
|
± 5%
|
|
Line Regulation
|
± 1%
|
± 1%
|
± 1%
|
-
|
-
|
-
|
-
|
± 1%
|
± 1%
|
|
Ripple & Noise
|
50mV
|
50mV
|
120mV
|
-
|
-
|
-
|
-
|
120mV
|
50mV
|
|
Input and Output Ratings: |
| |
|
Input
|
Output
|
|
Voltage
|
Frequency
|
Current
|
Watt
|
Load
|
+3.3V
|
+5V
|
+12V1
|
+12V2
|
+12V3
|
+12V4
|
-5V
|
-12V
|
+5Vsb
|
|
100-240 VAC
|
47-63 Hz
|
74 max
|
300W
|
Max. Load
|
28A
|
30A
|
18A
|
-
|
-
|
-
|
-
|
0.8A
|
2A
|
|
Min. Load
|
1.5A
|
0A
|
0.5A
|
-
|
-
|
-
|
-
|
0A
|
0A
|
|
|
NOTE:
- The +5 & +3.3 Volt combine total output shall not exceed 180W.
- The +5, +3.3 and +12 Volt combine total output shall not exceed 280W.
- Noise bandwidth is from DC to 20 MHz.
|
Agency Requirements : |
| |
Harmonic: Meet EN61000-3-2 strandards
EMI/RFI: CE, FCC class B, BSMI and CISPR class B
Safety: UL, cUL, CB, TUV, CCC |