EFRP-553 |
550 watts Output Power
N+1 Redundant Configuration
Meet 1U Rackmount System
Dimension: 98.5(W) x 40(H) x 267.7(D) mm |
Features : |
| |
Compact size Module Design
Quick Removable Application
Active Power Factor Correction
Universal Power Input
Current Sharing on +5V, +3.3V and +12V
Remote DC Sense on +5V, +3.3V
Front panel LED to Indicate Power Status
Power Fault Alarm Signals
Over Voltage Protection
Over Current Protection
Over Power Protection
Short Circuit Protection
MTBF >100,000 Hours |
General Specifications : |
| |
Input Range: 100 to 240 VAC
Power Factor: 0.98 minimum
Efficiency: >65% minimum, at full load
Hold up Time: 20mS minimum, at full load
PSON (Remote ON/OFF): TTL compatible
Power Good: 200 to 500 ms, TTL compatible
Cooling Fan: 38x38x28 mm
Operating Temperature: 0 to 40 ºC
Operating Humidity: 20 to 90 % |
Regulation, Ripple & Noise: |
| |
|
Output
|
+3.3V
|
+5V
|
+12V |
-12V
|
+5Vsb
|
|
Load Regulation
|
± 5%
|
± 5%
|
± 5% |
+9/-5%
|
± 5%
|
|
Line Regulation
|
± 1%
|
± 1%
|
± 1% |
± 1%
|
± 1%
|
|
Ripple & Noise
|
50mV
|
50mV
|
120mV |
120mV
|
50mV
|
|
Input and Output Ratings: |
| |
|
Input
|
Output
|
|
Voltage
|
Frequency
|
Current
|
Load
|
+3.3V
|
+5V
|
+12V
|
-12V
|
+5Vsb
|
|
100-240VAC
|
47-63Hz
|
10-5A
|
Max. Load
|
24A
|
20A
|
42A
|
0.8A
|
2or3A
|
| Min. Load |
1A
|
2A
|
1A
|
0A
|
0.1A
|
|
|
NOTE:
- The +5 & +3.3 Volt total output shall not exceed 140W
- Peak +12V DC output power should not exceed 45A peak for 12 sevonds.
- The +5, +3.3 and +12 Volt total output shall not exceed 540W
- Maximum continues total DC output power shout not exceed 550W.
|
Agency Requirements : |
| |
Harmonic: Meet EN61000-3-2
EMI/RFI: CE, FCC class B
Safety: UL, cUL, TUV, CB |
|