top
logo

Products

Banner
Banner
Banner
Banner

English
Search Solution:
Home News ETASIS Announces EFRP-M300 1U Redundant Power Supply Module
ETASIS Announces EFRP-M300 1U Redundant Power Supply Module Print E-mail

Announcement Highlights:

Features:
‧1U Dimension
‧ Short Circuit Protection
‧ Over Current Protection
‧ Over Voltage Protection
‧ Remote DC Sense on +5V and +3.3V
‧ MTBF >100,000 Hours@25˚C

Taipei, Taiwan - January 02, 2008
ETASIS ELECTRONICS a professional manufacturer of switching power supplies, proudly unveiled its EFRP-M300 redundant power supply module, which is deal for storage applications. In addition to these features listed above, the power supplies used in storage system must provide the power needs for processing big amounts of service with non-stop operation. Redundant power supplies are therefore becoming indispensable, allowing systems to operate continuously using a backup power supply unit if the main power supply unit is damaged, as well as enabling maintenance operations without the need to stop the system. The newly released EFRP-M300 is tailored to meet the needs of demanding high reliability in server fields.

Features and Characteristics
The power is 1U Type N+1 redundant power supply that features a full-range universal AC input from 100V to 240V +/-10 percent and a full-load power factor of more than 0.96 at 230V AC, 50Hz. It has 66A input current for 115V AC and 3A for 230V AC at 47Hz to 63Hz input frequencies. It supports active power factor correction and output current sharing for 3.3V, 5V ,12V and -12V output voltages. The unit has over-voltage, over-power and short-circuit protections, and comes with front panel LED power status indicator and alarm signals for fa???ulty power. It passed the 100 percent burn-in test, and has an MTBF of 100,000hrs. The 79x40x215mm unit is cooled by a 40mmx28mm DC fan. It has safety approvals, and meets CISPR22 (EN55022) Class A, FCC Part 1 and EN61000-3-2 standards for EMI/RFI/Harmonic.

Wide Range Oper??ation Temperature
EFRP-M300 can work at extremely harsh environment. All power-supply modules have current ratings that are based on some specific ambient temperature range. These current ratings should never be exceeded. The ambient temperature for a power supply is the temperature of the air immediately surrounding the power supply when it is operating with its associated equipment.

Input and Output Ratings:

Model No
Output
Voltage
Current
Watt
Load
+5V
+3.3V
+12V
-12V
5Vsb
EFRP-M300
90~264
VAC
6-3A
300W
Max Load
20A
20A
22A
0.8A
3.0A
Min Load
1A
1A
2A
0A
0.1A

Note: +3.3V and +5V total Output shall not exceed 25A, Total Output shall not exceed 300W

Regulation, Ripple & Noise:

Output+5V+3.3V+12V-12V5Vsb
Load Regulation±5%±5%±5%±5%±5%
Cross Regulation±5%±5%±5%±5%±5%
Line Regulation±1%±1%±1%±1%±1%
Ripple & Noise50mV50mV120mV120mV50mV

About ETASIS
ETASIS is one of the leading suppliers of standard switching power supplies. Founded in October 1996, ETASIS grew steadily, quickly acquiring a strong reputation for its high standards of quality and reliable products. Our research & development, engineering and marketing teams ensure that we stay in the lead by making sure that our products consistently meet and exceed the ever-changing needs of our customers.

All other product and company names herein may be trademarks of their registered owners.

Sales Contact:
Joe Su
Joe@etasis.com.tw
TEL:  886-2-2999-4858  ext: 200

Media Contact:
Johnson Huang
johnson_huang@etasis.com.tw
TEL:  886-2-2999-4858  ext: 260
Web Site: www.etasis.com.tw

 

bottom

Copyright © ETASIS Technology Corporation All Rights Reserved.